Control Room Solutions Task Team

Contacts

Our mission

The NASPI Control Room Solution Task Team’s mission is to work collectively with other NASPI task teams to advance the use of real-time synchrophasor applications for the purpose of improving control room operations and grid resilience and reliability. The CRSTT will use its experience and regional diversity to provide advice, direction, support and guidance to NASPI stakeholders and other organizations involved in the development and implementation of real-time synchrophasor applications.

CRSTT Work Plan, updated April 2021 (PDF).
Use case document; Mis-operations with PMU Data Summary Table (PDF).

Additional videos:
NASPI Oscillation Detection and Voltage Stability Workshop, Houston, TX, October 22, 2014; NASPI's YouTube Channel.
List of PMU versus SCADA Video Events Summary Videos (Updated April 2018, rev6).

Videos

Title Description Date
Video 5

Real and Reactive Power oscillations observed during a period of high wind generation.  During analysis of a system event in 2011, technical staff observed high frequency oscillations at multiple locations across the system, and correlated the oscillations with high amounts of wind generation.

Mar 20 2017
Video 4

Real and Reactive Power oscillations observed on the 69 kV system during a period of high wind generation with the plant radially connected (i.e. one of two normal source lines out of service).

Mar 20 2017
Video 3

Voltage oscillations observed following the loss of a 345 kV line during a period of high wind generation.

Mar 20 2017
Video 2

Voltage oscillations observed on the 230 kV system when a water pump was taken offline.

Mar 20 2017
Video 1

Current and voltage oscillations observed on the 138 kV system during testing of new generator controls (65 MW gas turbine).

Mar 20 2017

Documents

Title Description Date
Use Case: GEN-05 – Nuclear Plant Voltage Oscillations

In 2011, the Dominion System Operator requested a nuclear power plant to reduce its terminal voltage by 3 kV during light load conditions.

Jul 25 2017
EPG Synchrophasor Data File Format (.CSV) Apr 6 2017
EPG's Template Apr 6 2017
CRSTT: Using Synchrophasor Data during System Islanding Events and Blackstart Restoration

This paper explores the value that can be added in the near future by using synchrophasor data and applications in the areas of system islanding detection and blackstart restoration. It includes descriptions of:

  • Related functional entity roles and responsibilities
  • Ways that synchrophasor technology may be used to detect islanding events and aid entities in meeting certain restoration objectives
  • Related commercial applications that are currently on the market for which the NASPI CRSTT received information from application users or vendors

This paper may be updated in the future to include additional applications, functionality and methodologies as new information is provided.

Aug 26 2016
CRSTT: Using Synchrophasor Data for Phase Angle Monitoring

This paper addresses how synchrophasor technology can be used for phase angle monitoring and describes the various synchrophasor-based applications being used by electric utilities and grid operators presently. Uses for phase angle monitoring include:


• Wide-area situational awareness and visualization
• Line reclosing
• Verifying operation of synch check relays
• Setting alarms and alerts
• Improving state estimator solutions.


This paper may be updated in the future to include additional applications, update features of existing applications, functionality and methodologies as new information is received.

Aug 26 2016